To homeSend e-MailSite map
Find:
About Electric connectors Contact
  
  Electric Connectors:  
     LF Electric Connectors 
     RF Connectors 
     Connecting Receptacles for ICs 
     for Automotive Vehicle
     and Tractors
 
     New Developments 
  Certificate 
  Contact 
  e-Mail 
   

Connectors SNO49 (single), SNO50 (double) GEO.364.246 TU1

Connectors SNO49 (single), SNO50 (double) GEO.364.246 TU1
Type of mating:   cut-in
Types of backshells:   straight for equipment part
Number of contacts:   26, 38, 45, 57, 67
Mounting style:   point-to-point, crimping
Contact plating:   gold, silver
Operating temperatures range:   - 60 to +155C(gold) and to +100C (silver)
Operating current per each con:   5.0 11.0 A
Max operating voltage:   400 - 700 V
Number of nominal types:   20
Number of mating-unmating:   500
Shelf life, years:   15


Type of connector: rectangular low-frequency connectors of types SNO49 (single) and SNO50 (double) for high-density point-to-point wiring, for use in DC, AC current (frequency up to 3 MHz) and pulse current circuits.

The connectors may be equipment plugs and receptacles.

Design: equipment plugs and receptacles with backshell and without backshell.

Coupling: cut-in.

Contacts plating: Contacts are gold-plated, dia. 1.0 mm, 1.5 mm (GEO.364.246TU) or silver-plated, dia. 1.0 mm, 1.5 mm (GEO.364.246TU1), to be crimped.

Climatic performance: Connectors are designed in all-climate performance according to GOST V 20.39.404-81.

ORDERING DATA

Codification

SNO

49(50)

-26

4436

V(R)

-6(7)

(b)

-V

1

ype of connector

Design ordinal number:

49 single,

50 double

Number of contacts:

For SNO49: 26, 38, 45, 57, 67

For SNO50: 52, 64, 71, 76, 83, 90, 93, 95, 102, 105, 112, 114, 124, 134)

Plug (receptacle) size: length width, mm

For plug: 44x36 (SNO49), 63x44 (SNO50)

For receptacle: 43x34 (SNO49), 60x43 (SNO50)

Part of: V Plug, R Receptacle.

Design performance: 6 Equipment part without backshell,

7 Equipment part with backshell.

The additional designation (for SN50 only): Adding number of contacts per layouts 1 and 4

; b Adding number of contacts per layouts 2 and 3.

All-climate performance

Contact plating: gold less figure, 1 silver.

Notes: 1. Designations "" and "b" are introduces to distinguish between double connectors with number of contacts 83, which may repeat from adding of number of contacts when installing insulators according to layouts 1 ans 4, 2 ans 3.

2. In double connectors (SNO50) there is possibility of combination of nay of the two of five standard ratings of insulators, whereas in designation of number of contacts the number is put down equal to both insulators overall number of contacts installed in accordance with "" (TOP) marking on shell flanges.

How to order:

Plug SNO49-26/44x36V-6-V GEO.364.246 TU in bulk

Receptacle SNO50-83/60x43R-6b-V1 GEO.364.246 TU1 in bulk



   
 

 Ural Plant of Electric Connectors ISET (c) 2003-2006